Beads抗体-Anti-DYKDDDDK-Tag mAb (Magnetic Beads)(Same as Sigma's Anti-FLAG)

Datasheet

Application

Product Description

Binding capacity: 1mg of Flag fusion protein per 1ml of packed magnetic beads.

Specificity: ≥ 90% specificity towards Flag fusion proteins from mammalian and

bacterial cell extracts.

Product Description

Note: For antigens and protein: protein complexes requiring a special lysis buffer composed

of a different percentage of detergent, it is recommended to pretest the beads before use.

The Anti-Flag Magnetic beads are resistant to the many detergents at the

following concentrations: 5.0% Tween-20, 5.0% Triton X-100, 0.1% Igepal CA-630, 0.1% Chaps,

and 0.2% digitonin. It can also be used with 1.0 M NaCl or 1.0 M urea. See the Reagent Compatibility

Table for use with additional chemicals.

The following procedure is an example of a single immunoprecipitation reaction. For multiple

immunoprecipitation reactions, calculate the volume of reagents needed according to the number

of samples to be processed. For immunoprecipitation reactions, it is recommended to use 40 μl of the

10mg/ml bead suspension per reaction. Smaller amounts of beads (~10 μl volume, which binds 1 μg

Flag fusion protein) can be used.Note: Two control reactions are recommended for the procedure.

The first control is immunoprecipitation with the Polytag fusion protein (positive control) and the second

is a reagent blank with no protein (negative control).

4.1.Thoroughly resuspend the beads by gentle inversion. Make sure the bottle of Anti-Flag Magnetic Beads

is a uniform suspension. Remove an appropriate volume for use (see Table 1).

4.2.Place tube in the appropriate magnetic separator to collect the beads. Aspirate and discard storage buffer.

4.3.Wash the beads twice with 10beads volume of TBS (50 mM Tris HCl, 150 mM NaCl, pH 7.4) buffer. Be sure

most of the wash buffer is removed and no bead is discarded.

Note: For multiple immunoprecipitation samples, wash the total volume of beads needed for all samples

together. After washing, resuspend the beads in TBS buffer and divide the beads according to the number

of samples tested. Place tube in the appropriate magnetic separator to collect the beads. Remove and discard

TBS buffer.

4.4.Add 200~10 00 μl of c ell lysate to the washed beads. If necessary, bring the final volume to 1 ml by adding

lysis buffer (50 mM Tris HCl, pH 7.4, with 150 mM NaCl, 1 mM EDTA, and 1% Triton X-100). The volume of cell l

ysate to be used depends on the expression level of Flag fusion protein in  the transfected cells. For the positive

control, add 1 ml of TBS buffer and 4 μl of 100ng/μl Polytag fusion protein (~400 ng) to the washed beads. For the

negative control, add 1 ml of lysis buffer only with no protein. The amount of Polytag fusion protein to be precipitated

depends on the detection method. 400 ng of protein is sufficient for an activity assay or for an immunoblot analysis.

ForSDS-PAGE analysis with Coomassie blue or silver staining detection, use 2 μg of Po lytag fusion protein.

4.5.Agitate or shake (a roller shaker is recommended) all samples and controls gently for 2 hours.

In order to increase the binding efficiency, the binding step may be extended overnight.

4.6.Place tubes in the appropriate magnetic separator to collect the beads and remove the supernatant

with a narrow-end pipette tip.

4.7.Wash the beads three times with a total of 20 beads volumes of TBS-washing

buffer(50mM Tris HCl, 150mM NaCl, 250μM EDTA, 0.25% Triton X-100, 0.25% Na deoxycholate,

0.025% SDS, pH 7.4). Make sure all the supernatant is removed.

4.8.Elution of the Flag fusion proteins – Three elution methods are recommended according to protein

characteristics or further usage:

Protein elution under native conditions by competition with 3× Flag peptide. The elution efficiency is

very high using this method.

Elution under acidic conditions with 0.1 M glycine HCl, pH 3.0. This is a fast and efficient elution

method. Neutralization of the eluted protein with wash buffer may help preserve its activity.

Elution with sample buffer for gel electrophoresis and immunoblotting.

Elution w ith 3×Flag pep tide

5.1.Prepare 3×Flag elution solution. Dissolve 3×Flag peptide in 0.5 M Tris HCl, pH 7.5, with 1 M NaCl

at a concentration of 25 μg/μl. Dilute 5-fold with water to prepare a 3×Flag stock solution containing

5 μg/μl of 3×Flag peptide. For elution, add 3 μl of 5 μg/μl 3×Flag peptide stock solution to 100 μl of

TBS buffer (150 ng/μl final concentration).

5.2.Add 5 beads volumes of 3×Flag elution solution to each sample and control beads.

5.3.Incubate the samples and controls with gently shaking or on a rotator for 30 minutes at 2~8℃.

5.4.Place tube in the appropriate magnetic separator to collect the beads. Transfer the supernatants to

fresh tubes. Be careful not to transfer any beads.

5.5.Repeat steps 5.1-5.4, pooling elutes in the same tube.

5.6.For cleaning and storage of used beads, see steps 3.3 and 3.4.

Elution with 0.1 M Glycine HCl, pH 3.5

The procedure should be performed at room temperature. Do not leave the beads in this buffer more

than 20 minutes.

6.1.Add 5 beads volumes of 0.1 M glycine HCl buffer, pH 3.5, to each sample and control beads.

6.2.Incubate the samples and controls with gentle shaking or on a rotator for 5 minutes at room temperature.

6.3.Place tube in the appropriate magnetic separator to collect the beads. Transfer the supernatants to

fresh tubes containing 10 μl of 0.5 M Tris HCl, pH 7.4, with 1.5 M NaCl. Be careful not to transfer any beads.

6.4.Repeat steps 6.1-6.3, pooling eluates in same tube.

6.5.For immediate use, store the combined eluates at 2~8℃. Store at -20℃ for long

term storage.

6.6. For cleaning and storage of used beads, see steps 3.3 and 3.4.

Elution with SDS-PAGE Sample Buffer

The procedure should be performed at room temperature. Sample buffer should be at room

temperature before use.In order to minimize the denaturation and elution of the antibody, no reducing

agents, e.g., 2-mercaptoethanol or DTT, should be included in the sample buffer. The addition of

reducing agents will result in the dissociation of the heavy and light chains of the immobilized

antibody (25 and 50 kDa bands). If reducing conditions are absolutely necessary, a reducing

agent may be added. The final concentration of 2-mercaptoethanol or DTT in the 1× sample buffer

(62.5 mM Tris HCl, pH 6.8, 2% SDS, 10% (v/v) glycerol, and 0.002% bromphenol blue) should be 5%

or 50 mM, respectively.Note: Elution of the bound Flag fusion protein as a SDS-PAGE sample results

in damage to the Anti-Flag Magnetic Beads and they can not be used again. The SDS in the sample

buffer will denature the antibody and boiling will damage the bead structure.

7.1.Add 2 beads volume of 2×sample buffer (125 mM Tris HCl, pH 6.8, 4% SDS, 20% (v/v) glycerol,

and 0.004% bromphenol blue) to each sample and control.

7.2.Boil the sample and control tubes for 3 minutes.

7.3.Place tubes in the appropriate magnetic separator to collect the beads. Transfer the supernatants

to fresh tubes. The samples and controls are ready for loading on SDS-PAGE and immunoblotting

using Anti-Flag or specific antibodies against the fusion protein.

Magnetic bead diameter

 200-300nm

Conjugation

 Anti-flag monoclonal antibody

Storage Condition

Volume:1ml;10mg magnetic beads, supplied as a 10% suspension(w/v)

in 10mM sodium phosphate, 150mM sodium chloride, pH 7.4, and

0.01% (v/v) Proclin 300.

The beads are recommended to be stored at 2~8℃. The product is stable for

24 months at 2~8℃. Freezing the magnetic beads will irreversibly damage

the bead structure.

Isolation of fusion proteins containing flag tag sequence

RRID

AB_2936270

Application Image

Application

Application

Application

M20118

货号 规格 价格(¥)
M20118L 5000μl
M20118M 1000μl
M20118S 500μl

以上产品均有现货供应

订购咨询 orders@ab-mart.com

技术支持 service3@ab-mart.com

订货热线 4006-123-828

经销商名录:点击查看


Note:  Application as IHC, only suitable for histochemical staining or fluorescence staining of paraffin-embedded sections. Application as ICC/IF, suitable for histochemical or fluorescent staining of frozen sections, as well as chemical and fluorescent staining at the cellular level.

注意:抗体应用为IHC的,抗体只适合于石蜡切片的组化染色或者荧光染色。

抗体应用为IF/ICC的,抗体适合于冰冻切片的组化染色或者荧光染色,以及细胞水平的化学染色和荧光染色。

艾比玛特医药科技(上海)有限公司
上海市徐汇区桂平路333号聚科生物园区1号楼1-3层

邮箱:market@ab-mart.com

应聘职位:hr@ab-mart.com

订购专线:4006-123-828

销售电话:13162017139(微信同号)

技术支持:15618194176(微信同号)

南方经销商负责:手机13122837132(微信同号)          
北方及西南经销商负责:手机13122150513(微信同号)

6380582812748833035900295.jpg

微信客服

邮箱:market@ab-mart.com

应聘职位:hr@ab-mart.com

订购专线:4006-123-828

销售电话:13162017139(微信同号)

技术支持:15618194176(微信同号)

总机:021-34695901

南方经销商负责:手机13122837132(微信同号)          
北方及西南经销商负责:手机13122150513(微信同号)

6380582812748833035900295.jpg

微信客服

沪ICP备17056956号-2    艾比玛特医药科技(上海)有限公司